黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產品中心

二十碳五烯酸(EPA)酶聯免疫吸附檢測試劑盒
一鍵復制產品信息
ELK9817
規格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: EPA(Eicosapentaenoic Acid) ELISA Kit
Reactivity: General
Alternative Names: Icosapentaenoic Acid; Timnodonic Acid
Assay Type: Competitive Inhibition
Sensitivity: 0.13 ng/mL
Standard: 20 ng/mL
Detection Range: 0.31-20 ng/mL
Sample Type: serum, plasma, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Biochemicals
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with EPA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to EPA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of EPA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 0.179 0.000
10.00 0.397 0.000
5.00 0.689 0.000
2.50 0.812 0.000
1.25 1.275 0.000
0.63 1.557 0.000
0.32 1.887 0.000
0.00 2.132 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant EPA and the recovery rates were calculated by comparing the measured value to the expected amount of EPA in samples.
Matrix Recovery range Average
serum(n=5) 82-98% 90%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of EPA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 91-104% 87-99% 85-96% 87-101%
EDTA plasma(n=5) 89-102% 88-103% 79-90% 95-102%
Heparin plasma(n=5) 89-96% 87-98% 85-93% 87-98%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉