黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產品中心

人補體1抑制因子(C1INH)酶聯免疫吸附檢測試劑盒
一鍵復制產品信息
ELK1923
規格: 價格:
48T ¥1820.00
96T ¥2600.00
96T*5 ¥11050.00

Overview

Product name: Human C1INH(Complement 1 Inhibitor) ELISA Kit
Reactivity: Human
Alternative Names: SERPING1; C1IN; C1-INH; C1NH; HAE1; HAE2; Serpin Peptidase Inhibitor Clade G Member 1; Angioedema Hereditary; C1 Inhibitor; C1 Esterase Inhibitor
Assay Type: Sandwich
Sensitivity: 1.42 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Immune molecule;
Uniprot ID: P05155
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human C1INH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human C1INH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human C1INH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human C1INH in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
200.00 1.983 1.898
100.00 1.638 1.553
50.00 1.067 0.982
25.00 0.872 0.787
12.50 0.567 0.482
6.25 0.335 0.250
3.13 0.179 0.094
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant C1INH and the recovery rates were calculated by comparing the measured value to the expected amount of C1INH in samples.
Matrix Recovery range Average
serum(n=5) 98-104% 102%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 96-104% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C1INH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-95% 85-96% 89-100% 85-96%
EDTA plasma(n=5) 95-104% 82-96% 92-105% 83-92%
Heparin plasma(n=5) 86-93% 91-105% 87-99% 99-105%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉