小鼠透明質(zhì)酸酶(HAase)微量上樣酶聯(lián)免疫吸附檢測試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK10605MS
規(guī)格: 價格:
48T ¥1820.00
96T ¥2600.00
96T*5 ¥11050.00

Overview

Product name: Mouse HAase(Hyaluronidase) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: Hyaluronic Lase; Hyaluroniclase
Assay Type: Sandwich
Sensitivity: 1.16 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Hepatology;
Uniprot ID: Q3UZE4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse HAase. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse HAase. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse HAase, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse HAase in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
200.00 2.168 2.082
100.00 1.608 1.522
50.00 1.106 1.020
25.00 0.953 0.867
12.50 0.558 0.472
6.25 0.358 0.272
3.13 0.229 0.143
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HAase and the recovery rates were calculated by comparing the measured value to the expected amount of HAase in samples.
Matrix Recovery range Average
serum(n=5) 91-108% 100%
EDTA plasma(n=5) 82-92% 87%
Heparin plasma(n=5) 82-88% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HAase and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-90% 88-106% 93-99% 84-112%
EDTA plasma(n=5) 92-107% 94-114% 94-115% 88-102%
Heparin plasma(n=5) 87-98% 94-108% 86-99% 87-94%