黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產品中心

人TNF受體關聯因子6(TRAF6)微量上樣酶聯免疫吸附檢測試劑盒
一鍵復制產品信息
ELK10562MS
規格: 價格:
48T ¥1820.00
96T ¥2600.00
96T*5 ¥11050.00

Overview

Product name: Human TRAF6(TNF Receptor Associated Factor 6) Microsample ELISA Kit
Reactivity: Human
Alternative Names: RNF85; E3 ubiquitin-protein ligase TRAF6; Interleukin-1 signal transducer
Assay Type: Sandwich
Sensitivity: 98.4 ng/mL
Standard: 20 μg/mL
Detection Range: 0.32-20 μg/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;
Uniprot ID: Q9Y4K3
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TRAF6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TRAF6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TRAF6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TRAF6 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.180 2.087
10.00 1.600 1.507
5.00 1.042 0.949
2.50 0.851 0.758
1.25 0.511 0.418
0.63 0.356 0.263
0.31 0.254 0.161
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TRAF6 and the recovery rates were calculated by comparing the measured value to the expected amount of TRAF6 in samples.
Matrix Recovery range Average
serum(n=5) 82-91% 87%
EDTA plasma(n=5) 85-109% 97%
Heparin plasma(n=5) 86-103% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TRAF6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-113% 91-116% 83-101% 88-110%
EDTA plasma(n=5) 89-107% 83-113% 82-96% 87-104%
Heparin plasma(n=5) 93-111% 85-115% 86-118% 86-108%

產品成分表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉