黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產(chǎn)品中心

人CD83分子(CD83)微量上樣酶聯(lián)免疫吸附檢測試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK10536MS
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00
96T*5 ¥10200.00

Overview

Product name: Human CD83(Cluster Of Differentiation 83) Microsample ELISA Kit
Reactivity: Human
Alternative Names: BL11; HB15; Activated B Lymphocytes,Immunoglobulin; B-cell activation protein; Cell surface protein HB15
Assay Type: Sandwich
Sensitivity: 18.5 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Infection immunity;Immune molecule;Dermatology;
Uniprot ID: Q01151
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CD83. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CD83. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CD83, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CD83 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.258 2.172
2500.00 1.564 1.478
1250.00 0.994 0.908
625.00 0.799 0.713
312.50 0.610 0.524
156.25 0.385 0.299
78.13 0.245 0.159
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CD83 and the recovery rates were calculated by comparing the measured value to the expected amount of CD83 in samples.
Matrix Recovery range Average
serum(n=5) 82-102% 92%
EDTA plasma(n=5) 81-118% 100%
Heparin plasma(n=5) 87-107% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD83 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 94-108% 88-100% 82-92% 88-98%
EDTA plasma(n=5) 87-118% 89-95% 81-98% 93-102%
Heparin plasma(n=5) 89-105% 89-98% 84-105% 89-101%

產(chǎn)品成分表

關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉