黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產品中心

小鼠幾丁質酶樣蛋白(YM1)微量上樣酶聯(lián)免疫吸附檢測試劑盒
一鍵復制產品信息
ELK0631MS
規(guī)格: 價格:
48T ¥1820.00
96T ¥2600.00
96T*5 ¥11050.00

Overview

Product name: Mouse YM1(Chitinase 3-like 3) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: Chil3; Beta-N-acetylhexosaminidase Ym1; Chitinase-3-like protein 3; ECF-L; Eosinophil chemotactic cytokine; Secreted protein Ym1
Assay Type: Sandwich
Sensitivity: 36.1 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;
Uniprot ID: O35744
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse YM1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse YM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse YM1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse YM1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
4000.00 2.145 2.054
2000.00 1.667 1.576
1000.00 1.245 1.154
500.00 0.816 0.725
250.00 0.548 0.457
125.00 0.267 0.176
62.50 0.167 0.076
0.00 0.091 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant YM1 and the recovery rates were calculated by comparing the measured value to the expected amount of YM1 in samples.
Matrix Recovery range Average
serum(n=5) 93-106% 100%
EDTA plasma(n=5) 91-112% 102%
Heparin plasma(n=5) 94-105% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of YM1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-94% 91-106% 84-108% 92-102%
EDTA plasma(n=5) 94-109% 83-115% 85-107% 89-102%
Heparin plasma(n=5) 90-115% 81-107% 85-100% 93-113%

產品成分表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉