黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產品中心

人脂肪酸轉運蛋白4(FATP4)微量上樣酶聯免疫吸附檢測試劑盒
一鍵復制產品信息
ELK0459MS
規格: 價格:
48T ¥1820.00
96T ¥2600.00
96T*5 ¥11050.00

Overview

Product name: Human FATP4(Fatty Acid Transport Protein 4) Microsample ELISA Kit
Reactivity: Human
Alternative Names: SLC27A4; ACSVL4; Solute carrier family 27 member 4; Very long-chain acyl-CoA synthetase 4
Assay Type: Sandwich
Sensitivity: 0.064 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;
Uniprot ID: Q6P1M0
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FATP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FATP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FATP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FATP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.521 2.427
5.00 1.535 1.441
2.50 1.157 1.063
1.25 0.715 0.621
0.63 0.561 0.467
0.31 0.305 0.211
0.16 0.231 0.137
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FATP4 and the recovery rates were calculated by comparing the measured value to the expected amount of FATP4 in samples.
Matrix Recovery range Average
serum(n=5) 81-117% 99%
EDTA plasma(n=5) 92-129% 111%
Heparin plasma(n=5) 81-105% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FATP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-114% 81-118% 90-118% 82-91%
EDTA plasma(n=5) 81-104% 82-97% 91-109% 85-116%
Heparin plasma(n=5) 87-104% 82-112% 93-106% 86-112%

產品成分表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉