黄瓜视频苹果直接安装|天津女王招奴|精品国产综合久久久久紧|AV成人一区二区三区在线看|成版人APP网站|一次一次凶猛有力的索要|迷情都市游戏

產(chǎn)品中心

大鼠鐵調(diào)素25(Hepc 25)微量上樣酶聯(lián)免疫吸附檢測(cè)試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK0389MS
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00
96T*5 ¥11900.00

Overview

Product name: Rat Hepc 25(Hepcidin 25) Microsample ELISA Kit
Reactivity: Rat
Alternative Names: Hamp; HEPC; Hepc20; Hepc25; HEPCIDIN; Hepcidin 20; Hepcidin 25; Hepcidin antimicrobial peptide; Hepcidin-20; Hepcidin25; HFE2; HFE2B; LEAP 1; LEAP-1; LEAP1; Liver expressed antimicrobial peptide; Liver-expressed antimicrobial peptide 1; PLTR; Putative liver tumor regressor
Assay Type: Sandwich
Sensitivity: 0.62 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Endocrinology;Hematology;Genetic science;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat Hepc 25. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat Hepc 25. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat Hepc 25, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat Hepc 25 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
100.00 2.164 2.068
50.00 1.533 1.437
25.00 1.137 1.041
12.50 0.800 0.704
6.25 0.427 0.331
3.13 0.329 0.233
1.56 0.220 0.124
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Hepc 25 and the recovery rates were calculated by comparing the measured value to the expected amount of Hepc 25 in samples.
Matrix Recovery range Average
serum(n=5) 88-96% 92%
EDTA plasma(n=5) 89-111% 100%
Heparin plasma(n=5) 83-113% 98%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hepc 25 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 82-98% 91-109% 81-113%
EDTA plasma(n=5) 86-96% 88-105% 80-108% 92-98%
Heparin plasma(n=5) 92-118% 82-100% 83-89% 89-106%

產(chǎn)品成分表

關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉